11.3.1 Active Model

The GCU maintains a single active model. This model is always derived from the in-memory configuration file. The configuration file can be from a Galaxy console or from a file-based, single-instance Galaxy on any Alpha system. Regardless of its source, console callbacks maintain the integrity of the file. The GCU utilizes Galaxy event services to determine when a configuration change has occurred. When a change occurs, the GCU parses the configuration file and updates its active model to reflect the current system. The active model is not saved to a file unless you choose to save it as an offline model. Typically, the active model becomes the basis for creating additional models. When creating models, it is generally best to do so online so that you are sure your offline models can engage when they are needed.

11.3.2 Offline Models

The GCU can load any number of offline Galaxy configuration models and freely switch among them, assuming they were created for the specific system hardware. The model representation is a simple ASCII data definition format.

You should never need to edit a model file in its ASCII form. The GCU models and ruleset adhere to a simple proprietary language known as the Galaxy Configuration Language (GCL). This language continues to evolve as needed to represent new Galaxy innovations. Beware of this fact if you decide to explore the model and ruleset files directly. If you accidentally corrupt a model, you can always generate another. If you corrupt the ruleset, you may need to download another from the OpenVMS Galaxy website.

11.3.2.1 Example: Creating an Offline Model

To create an offline Galaxy configuration model:

  1. Boot your Galaxy system, log in to the system account, and run the GCU.
  2. By default, the GCU displays the active model.
  3. Disengage the active model by clicking the Engage button (it toggles).
  4. Assuming your system has a few secondary CPUs, drag and drop some of the CPUs to a different Galaxy instance.
  5. Save the model by selecting Save Model from the Model menu. Give the model a suitable name with a .GCM extension. It is useful to give the model a name that denotes the CPU assignments; for example, such as G1x7.GCM for a system in which instance 0 has 1 CPU and instance 1 has 7 CPUs, or G4x4.GCM for a system with 4 CPUs on each of its two instances. This naming scheme is optional, but be sure to give the file the proper .GCM extension.
    You can create and save as many variations of the model as you like.

To engage an offline model:

  1. Run the GCU.
  2. By default, the GCU displays the active model. You can close the active model or just leave it.
  3. Load the desired model by selecting Open Model from the Model menu.
  4. Locate and select the desired model and click OK. The model will be loaded and displayed in an offline, disengaged state.
  5. Click the Engage button to reengage the model.
  6. The GCU will display any management operations required to engage the model. If you approve of the actions, click OK. The GCU will perform the management actions, and the model will be displayed as active and engaged.

11.4 Using the GCU Charts

The Galaxy Configuration File contains a considerable amount of configuration data and can grow quite large for complex Galaxy configurations. If the GCU displayed all the information it has about the system, the display would become unreasonably complex. To avoid this problem, the GCU provides Galaxy charts. Charts are simply a set of masks that control the visibility of the various components, devices, and interconnections. The entire component hierarchy is present, but only the components specified by the selected chart are visible. Selecting a different chart alters the visibility of component subsets.

By default, the GCU provides five preconfigured charts. Each is designed to show a specific component relationship. Some GCU command operations can be performed only within specific charts. For example, you cannot reassign CPUs from within the Physical Structure chart. The Physical Structure chart does not show the Galaxy instance components, thus you would have no target to drag and drop a CPU on. Because you can modify the charts the GCU does not restrict its menus and command operations to specific chart selections. In some cases, the GCU displays an informational message to help you select an appropriate chart.

11.4.1 Component Identification and Display Properties

Each component has a unique identifier. This identifier can be a simple sequential number, such as with CPU IDs, a physical backplane slot number, as with I/O adapters, or a physical address, as with memory devices. Each component type is also assigned a shape and color by the GCU. Where possible, the GCU further distinguishes each component using supplementary information it gathers from the running system.

The display properties of each component are assigned within the Galaxy Configuration Ruleset (SYS$MANAGER:GALAXY.GCR). You should not edit this file, except to customize certain display properties, such as window color or display text style.

The text that gets displayed about each component is also customizable. Each component type has a set of statements in the ruleset that determine its appearance, data content, and interaction.

One useful feature is the ability to select which text is displayed in each component type on the screen. The device declaration in the ruleset allows you to specify the text and parameters, which make up the display text statement. A subset of this display text is displayed whenever the zoom scale factor does not allow the full text to be displayed. This subset is known as the mnemonic. The mnemonic can be altered to include any text and parameters.

11.4.2 Physical Structure Chart

The Physical Structure chart describes the physical hardware in the system. The large rectangular component at the top, or root, of the chart represents the physical system cabinet itself. Typically, below the root, you will find physical components such as modules, slots, arrays, adapters, and so on. The type of components presented and the depth of the component hierarchy is directly dependent on the level of support provided by the console firmware for each hardware platform. If you are viewing a single-instance Galaxy on any Alpha system, then only a small subset of components can be displayed. As a general rule, the console firmware presents components only down to the level of configurable devices, typically to the first-level I/O adapter or slightly beyond. It is not a goal of the GCU or of the Galaxy console firmware to map every device, but rather those that are of interest to Galaxy configuration management.

The Physical Structure chart is useful for viewing the entire collection of components in the system; however, it does not display any logical partitioning of the components.

In the Physical Structure chart you can:

11.4.2.1 Hardware Root

The topmost component in the Physical Structure chart is known as the hardware root (HW_Root). Every Galaxy system has a single hardware root. It is useful to think of this as the physical floorplan of the machine. If a physical device has no specific lower place in the component hierarchy, it will appear as a child of the hardware root. A component that is a child can be assigned to other devices in the hierarchy when the machine is partitioned or logically defined.

Tip

Clicking the root instance of any chart will perform an auto-layout operation if the Auto Layout mode is set.

11.4.2.2 Ownership Overlay

Choose Ownership Overlay from the Windows menu to display the initial owner relationships for the various components. These relationships indicate the instance that will own the component after a power cycle. Once a system has been booted, migratable components may change owners dynamically. To alter the initial ownership, the console environment variables must be changed.

The ownership overlay has no effect on the Physical Structure chart or the Failover Target chart.

11.4.3 Logical Structure Chart

The Logical Structure chart displays Galaxy communities and instances and is the best illustration of the relationships that form the Galaxy. Below these components are the various devices they currently own. Ownership is an important distinction between the Logical Structure chart and Physical Structure chart. In a Galaxy, resources that can be partitioned or dynamically reconfigured have two distinct "owners".

The owner describes where the device will turn up after a system power up. This value is determined by the console firmware during bus-probing procedures and through interpretation of the Galaxy environment variables. The owner values are stored in console nonvolatile memory so that they can be restored after a power cycle.

The current_owner describes the owner of a device at a particular moment in time. For example, a CPU is free to reassign among instances. As it does, its current_owner value is modified, but its owner value remains whatever it was set to by the lp_cpu_mask# environment variables.

The Logical Structure chart illustrates the current_owner relationships. To view the nonvolatile owner relationships, select Ownership Overlay from the Window menu.

11.4.3.1 Software Root

The topmost component in the Logical Structure chart is known as the software root (SW_Root). Every Galaxy system has a single software root. If a physical device has no specific owner, it will appear as a child of the software root. A component that has a child can be assigned to other devices in the hierarchy when the machine is logically defined.

Tip

Clicking the root instance of any chart will perform an auto layout operation if the Auto Layout mode is set.

11.4.3.2 Unassigned Resources

You can configure Galaxy partitions without assigning all devices to a partition, or you can define but not initialize one or more partitions. In either case, some hardware may be unassigned when the system boots.

The console firmware handles unassigned resources in the following manner:

Devices that remain unassigned after the system boots will appear assigned to the software root component and may not be accessible.

11.4.3.3 Community Resources

Resources such as shared memory can be accessed by all instances within a sharing community. Therefore, for shared memory, the community itself is considered the owner.

11.4.3.4 Instance Resources

Resources that are currently or permanently owned by a specific instance are displayed as children of the instance component.

11.4.4 Memory Assignment Chart

The Memory Assignment chart illustrates the partitioning and assignment of memory fragments among the Galaxy instances. This chart displays both hardware components (arrays, controllers, and so on) and software components (memory fragments).

Current Galaxy firmware and operating system software does not support dynamic reconfiguration of memory. Therefore, the Memory Assignment chart reflects the way the memory address space has been partitioned by the console among the Galaxy instances. This information can be useful for debugging system applications or for studying possible configuration changes.

11.4.4.1 Console Fragments

The console requires one or more small fragments of memory. Typically, a console allocates approximately 2MB of memory in the low address range of each partition. This varies by hardware platform and firmware revision. Additionally, some consoles allocate a small fragment in high address space for each partition to store memory bitmaps. The console firmware may need to create additional fragments to enforce proper memory alignment.

11.4.4.2 Private Fragments

Each Galaxy instance is required to have at least 64MB of private memory (includes the console fragments) to boot OpenVMS. This memory can consist of a single fragment, or the console firmware may need to create additional private fragments to enforce proper memory alignment.

11.4.4.3 Shared Memory Fragments

To create an OpenVMS Galaxy, a minimum of 8MB of shared memory must be allocated. This means the minimum memory requirement for an OpenVMS Galaxy is actually 72MB (64MB for a single instance, and 8MB for shared memory).

11.4.5 CPU Assignment Chart

The CPU Assignment chart displays the minimal number of components required to reassign CPUs among the Galaxy instances. This chart can be useful for working with very large Galaxy configurations.

11.4.5.1 Primary CPU

Each primary CPU is displayed as an oval rather than a hexagon. This is a reminder that primary CPUs cannot be reassigned or stopped. If you attempt to drag and drop a primary CPU, the GCU displays an error message in its status bar and does not allow the operation to occur.

11.4.5.2 Secondary CPUs

Secondary CPUs are displayed as hexagons. Secondary CPUs can be reassigned among instances in either the Logical Structure chart or the CPU Assignment chart. Simply drag and drop the CPU on the desired instance. If you drop a CPU on the same instance that currently owns it, the CPU will be stopped and restarted.

11.4.5.3 Fast Path and Affinitized CPUs

If you reassign a CPU that has a Fast Path device currently affinitized to the CPU, the affinity device will move to another CPU and the CPU reassignment will suceed. If a CPU has current process affinity assignment, the CPU cannot be reassigned.

For more information about using OpenVMS Fast Path features, see the OpenVMS I/O User's Reference Manual.

11.4.5.4 Lost CPUs

You can reassign secondary CPUs to instances that are not yet booted (partitions).

Similarly, you can reassign a CPU to an instance that is not configured as a member of the Galaxy sharing community. In this case, you can push the CPU away from its current owner instance, but you cannot get it back unless you log in to the independent instance (a separate security domain) and reassign the CPU back to the current owner.

Regardless of whether an instance is part of the Galaxy sharing community or is an independent instance, it will still be present in the Galaxy configuration file; therefore, the GCU will still be able to display it.

11.4.6 IOP Assignment Chart

The IOP Assignment chart displays the current relationship between I/O modules and the Galaxy instances. Note that, depending on what type of hardware platform is being used, a single-instance Galaxy on any Alpha system may not show any I/O modules in this display.

11.4.7 Failover Target Chart

The Failover Target chart shows how each processor will automatically fail over to other instances in the event of a shutdown or failure. Additionally, this chart illustrates the state of each CPU's autostart flag.

For each instance, a set of failover objects are shown, representing the full set of potential CPUs. By default, no failover relationships are established and all autostart flags are set.

To establish automatic failover of specific CPUs, drag and drop the desired failover object to the instance you want the associated CPU to target. To set failover relationships for all CPUs owned by an instance, drag and drop the instance object on top of the instance you want the CPUs to target.

To clear individual failover targets, drag and drop a failover object back to its owner instance. To clear all failover relationships, right-click on the instance object to display the Parameters & Commands dialog box, click on the Commands button, click the "Clear ALL failover targets?", button and then click OK.

By default, whenever a failover operation occurs, the CPUs will automatically start once they arrive in the target instance. You can control this autostart function using the autostart commands found in the Parameters & Commands dialog box for each failover object, or each instance object. The Failover Target chart displays the state of the autostart flag by displaying the failover objects in green if autostart is set, and red if autostart is clear.

Please note the following restrictions in the current implementation of failover and autostart management:

11.5 Viewing Component Parameters

Each component has a set of parameters that can be displayed and, in some cases, altered. To display a component's parameters, position the cursor on the desired component, click the right mouse button, and select the Parameters item from the pop-up menu entry. Alternately, you can select a component, then select the Parameters item from the Components menu.

Where parameters are subject to unit conversion, changing the display unit will update the display and any currently visible parameter dialog boxes. Other parameters represent a snapshot of the system component and are not dynamically updated. If these parameters change, you must close and then reopen the Parameters dialog box to see the updated values.

11.6 Executing Component Commands

A component's Parameters dialog box can also contain a command page. If so, you can access the commands by clicking on the Commands button at the top of the dialog box. Most of the commands are executed by clicking on their toggle buttons and then clicking the OK or Apply buttons. Other commands may require that you enter information, or select values from a list or option menu. Note that if you select several commands, they will be executed in a top-down order. Be sure to choose command sequences that are logical.

11.7 Customizing GCU Menus

System Managers can extend and customize the GCU menus and menu entries by creating a file named SYS$MANAGER:GCU$CUSTOM.GCR. The file must contain only menu statements formatted as illustrated in the following examples. The GCU$CUSTOM.GCR file is optional. It will be preserved during operating system upgrades.


FORMAT EXAMPLE: 
 
  MENU "Menu-Name" "Entry-Name" Procedure-type "DCL-command" 
  
      * Menu-Name - A quoted string representing the name of the 
                    pulldown menu to add or extend. 
 
      * Entry-Name - A quoted string representing the name of the 
                    menu entry to add. 
 
      * Procedure-type - A keyword describing the type of procedure 
                    to invoke when the menu entry is selected. 
 
        Valid Procedure-type keywords include: 
 
        COMMAND_PROCEDURE - Executes a DCL command or command file. 
        SUBPROC_PROCEDURE - Executes a DCL command in subprocess context. 
 
      * DCL-command - A quoted string containing a DCL command statement 
                     consisting of an individual command or invokation 
                     of a command procedure. 

To create a procedure to run on other instances, create a command procedure that uses SYSMAN or task-to-task methods similar to what the GCU uses in SYS$MANAGER:GCU$ACTIONS.COM. You can extend GCU$ACTIONS.COM, but this file will be replaced during operating system upgrades and is subject to change.


  EXAMPLE MENU STATEMENTS (place in SYS$MANAGER:GCU$CUSTOM.GCR): 
 
  // GCU$CUSTOM.GCR - GCU menu customizations 
  // Note that the file must end with the END-OF-FILE statement. 
  // 
  MENU "Tools" "Availability Manager" SUBPROC_PROCEDURE "AVAIL/GROUP=DECamds" 
  MENU "Tools" "Create DECterm" COMMAND_PROCEDURE  "CREATE/TERM/DETACH" 
  MENU "DCL"   "Show CPU"       COMMAND_PROCEDURE  "SHOW CPU" 
  MENU "DCL"   "Show Memory"    COMMAND_PROCEDURE  "SHOW MEMORY" 
  MENU "DCL"   "Show System"    COMMAND_PROCEDURE  "SHOW SYSTEM" 
  MENU "DCL"   "Show Cluster"   COMMAND_PROCEDURE  "SHOW CLUSTER" 
  END-OF-FILE 

11.8 Monitoring an OpenVMS Galaxy with DECamds

The DECamds availability manager software provides a valuable real-time view of the Galaxy system. DECamds can monitor all Galaxy instances from a single workstation or PC anywhere on the local area network. DECamds utilizes a custom OpenVMS driver (RMDRIVER) that periodically gathers availability data from the system. This information is returned to the DECamds client application using a low-level Ethernet protocol. The client application provides numerous views and graphs of the system's availability characteristics. Additionally, when DECamds detects one of numerous known conditions, it notifies the user and offers a set of solutions (called fixes) that can be applied to resolve the condition.

Every OpenVMS system comes with the DECamds Data Collector (RMDRIVER) installed. To enable the collector, you must execute its startup procedure inside SYSTARTUP_VMS.COM or manually on each Galaxy instance you want to monitor. Use the following commands to start the data collector:


$ @SYS$STARTUP:AMDS$STARTUP START or STOP 

Prior to starting the collector, you need to specify a group name for your Galaxy. Do so by editing the file SYS$COMMON:[AMDS]AMDS$LOGICALS.COM. This file includes a statement for declaring a group name. Choose any unique name, making sure this file on each Galaxy instance contains the same group name.

When using DECamds, OpenVMS Engineering finds it useful to display the System Overview window, the Event window, and a CPU Summary window for each Galaxy instance. There are a number of additional views you can monitor depending on your specific interests. For more information about DECamds, refer to the DECamds Users Guide.